Laser Type:CO2
Wavelength:10,600nm
Laser Emission Mode:Pulsed
Output Power:60 watts (maximum peak)
Laser Beam Energy:Variable from 1 – 90 mJ
Pulse Repetition Rate:Up to 16.7 kHz
Pulse Duration:20 – 3000 usec
Power Stability:± 1.5 watts (±5%)
Mode Quality:(M²) < 1.2
Beam Size:Ø 1.8 ± 0.5 mm
Beam Divergence:7.5 ± 0.5 mrad (full angle)
Polarization:> 100:1 linear (orthogonal to mounting pads)
Maximum Scan Area:10 mm diameter
Aiming Laser:5 mW, 650 nm (red) diode laser
Articulated Arm:Lightweight, aluminum fiber, 7-joint, pneumatically balanced
Treatment radius at full arm extension:85 cm (33.5″)
Horizontal rotation:360°
Lens Assemblies:150 um spot size, 120 um spot size:(optional)
Handpiece:Multi-use Aesthetic or surgical hand piece
User Interface:10.4″ high-resolution
Laser Emission Control:Footswitch
Laser Emission Indicators:Solid amber LED in Standby and Ready modes
Flashing:red LED during laser emission
Electrical Requirements:100 – 240 VAC self-sensing, 50/60 Hz, 7.1 A, single phase
Dimensions:40 cm x 44 cm x 177 cm, (15.75″ x 17.3″ x 70″)
Weight:26 kg (58 lbs)
Operating Modes
Mode:[ Energy Settings ] [ Fractional Coverage ] [ Estimated Ablation Depth ]
CO2RE Light:[18 – 74.5 mJ] [30 – 50%] [20 – 40 um]
CO2RE Mid:[45 – 257 mJ] [20 – 40%] [100 – 200 um]
CO2RE Deep:[30 – 70 mJ] [1 – 5%] [500 – 750 um]
CO2RE Fusion:[45 – 128 mJ, 30 – 70 mJ] [20 – 40%] [100 – 200 μm & 500 – 750 um]
Classic Resurfacing:[1 – 10 mJ] [Full] [100 – 200 um]
Dermal Excision:[5 – 40 mJ] [N/A] [0.2 mm x selected line 0.2 mm freehand]
First fully integrated CO2 laser, worldwide.
Designed to adapt to your patients needs, with 100+ indications.
What CO2RE Is For
100+ indications cleared in 10 medical specialties, including dermatology, plastic surgery, and gynecology.
Imagine having one system designed for numerous procedures that require excision, incision, ablation, coagulation, and resurfacing of soft tissue. Its here. With the CO2RE system, you can precisely target and efficiently treat the skin with control.
Treat multiple skin layers in one pass
Perform full and fractional resurfacing
Enhance coagulation
Encourage neocollagenis
Industry-first internal scanner optimized for numerous individualized treatment applications
Key Benefits of the CO2RE System
Give your patients positive experiences and outcomes.
CO2RE treatments are fast and require limited downtime.
The system delivers proven, predictable, visible results across indications1-4, including:
Enhancing skin tone and texture through skin resurfacing
Reducing the effects of the sun and aging on the skin
Smoothing out fine lines, wrinkles, and surgical and acne scars
Gain unparalleled treatment flexibility that can help your practice grow.
Designed from the inside out to be a comprehensive work station:
CO2RE Aesthetics for skin resurfacing, from superficial to deep skin treatments, including several options and combinations tailored for your patients needs.
CO2RE Surgical for a true, continuous wave with efficient skin coagulation after the surgical cut.
CO2RE® Intima for gynecology applications, enabling you to broaden your portfolio offering.
CO2RE Product Features
Light
Light Peel
20-40 µm
Level with Stratum Comeum
Mid
Epidermal and dermal resurfacing
Coagulation
100-200 µm
Improve skin tone and texture
Complexion refresher
Deep
Deep fractional resurfacing
Deeper level coagulation
500-700 µm
Improve scars, fine lines and wrinkles
Fusion
Combination of superficial and deep fractional resurfacing
Superficial texture variations
Fine lines and wrinkles
What CO2RE Intima is For
The CO2RE® Intima system is uniquely engineered to transform treatment of many dermatological conditions, including gynecological needs.
The CO2RE Intimas comprehensive range of treatment options1 include:
Using well-established CO2 technology, you can now perform minimally invasive, non-hormonal, energy-based treatments of the introitus, vaginal canal, and external genitalia in your office, in as little as 10 minutes for each treatment.
Ablation and resurfacing of soft tissue
Scar tissue (e.g. C-section scar)
Conization of the cervix such as vulvar and vaginal intraepithelial neoplasia (VIN, VAIN)
Leukoplakia (vulvar dystrophies)
Condyloma acuminate
The systems customized handpieces are designed to treat the introitus, vaginal canal, and external genitalia.
Conveniently treat with pre-set or individualized treatment options
Accurately target and treat tissue with ergonomic, pen-like precision2
With 360o rotation capability for ease of use on tissue along the vaginal canal, and sterile for every patient, the single-use handpieces are guaranteed ready to use.
Significant benefits for your practice and patients.
Efficient procedural time as little as 10 minutes for each treatment
Minimally invasive, non-hormonal, energy-based treatment
Portable system allows you to easily perform office-based procedures, and is easy to move from room to room
Simple in-office setup for gynecological applications
Single-use handpiece optimizes workflow, enhancing patient safety
Financial savings single-use handpieces reduce staff time, administrative costs, and inefficiencies
Designed with your practice in mind.
The CO2RE Intima system offers numerous user-friendly, productivity-enhancing features.
Minimize physician fatigue with articulated arm and featherweight handpieces
Gynecology-specific selection of handpieces and lenses
Intuitive touch-screen interface stores and recalls user preferences
Precision internal scanner digitally synchronized with laser pulse generator
Compact, quiet, easily mobile, and portable
Well-established CO2 technology treats skin or soft tissue.
CO2 technology has been used in gynecology for benign and pre-malignant vulvar and cervical dysplasia since 1973.
The CO2RE system offers customizable treatment capability with handpiece and lens combinations to provide physician control. Compared to traditional surgical methods, it provides greater precision, cleaner incision, and less scarring.
There are no reviews yet.